The SerialLink input node provides all 24 GPI contact closure states.
Connect a Serial Link via TCP in the Connection Manager and set its TCP ID in the input node to listen to the incoming packets.
This node can be found under Nodes > Input > Devices > Serial Link GPI
TCP Connection ID:
Enter here the SerialLink's TCP Connection ID.
With Widget Designer version 6, all nodes support so called node commands. Node commands access functions (i.e methods) from a node and / or set a parameter (i.e. property).
Enter "Node", followed by the according ID and a dot and a list will pop up showing all available commands for the node. For instance, Node1.TintColor.SetRGB(125,0,255) colors the node in purple.
In addition, the node properties with a parameter ID (the small superscript number) can be edited via the command Node1.SetParam(ID,new Value) or WDNodeSetParam(NodeID,ParamID,Value).
The node generates the following output:
- Status for all 24 GPIs (True (10V)=1 or False (0V)=0)